The other valve manufactuerers Honwywell, White Rodgers and Robertshaw also had these valves. The pick and hold valves where first devloped by White Rodgers and used on gas dryers. They later found there way into use on heating systems and Robertshaw had a system also that was used with a mercury pilot. Oct 15, 2010. This is a BRAND NEW OEM Intertherm/Nordyne/Miller Mobile Home furnace Gas Valve! It's designed for STANDING PILOT Furnaces. The Intertherm Part # is 624583 (Robertshaw Model # is 7200ERCS-1) which replaces all the old #s listed below. Flip a brass fitting on the valve to convert it from NAT gas to LP gas.
Description:
24 Volt Factory model 7200ER 3/4' Inlet size 3/4' Outlet size Pressure regulator setting Uni-Kit Capacity 150,000 2 Reducer bushing Replaces most constant pilot gas valves
Inlet Conn.: 3/4'; Outlet Conn.: 3/4'; Bushings: Two 3/4' x 1/2'; Side Tap: No;
Specifications:
Dimensions: 4-1/8' W x 4-3/4' H x 2-29/32' D |Ambient temperature: -40째F to +175째F |Current: 0.2A |Capacity: 150,000 BtuH (at 3.5' W.C.) is universal for replacing most residential equipment |Pressure rating: 1/2 PSI maximum |NEC: Class 2 |Power consumption: 5 watts |Swing radius: 3-9/16' |Six-function valves incorporate manual valve, safety shut off magnet, dual automatic valves, main gas regulator and pilot adjustments |Features integral manual selector with four gas flow positions: OFF, ON, PILOT and SET |SET provides pilot-only gas flow during magnet energizing and lockup
Product Specifications
productTemplate.PopularityScore | 3.34 |
productTemplate.ProductSearchType | Gas Valves |
Inlet Conn. | 3/4' |
Outlet Conn. | 3/4' |
productTemplate.360PathImage | 00001/835-720-406 |
Side Tap | No |
Bushings | Two 3/4' x 1/2' |
Shipping Weight | 2.35 |
Shipping Width | 4.70 |
Shipping Length | 5.80 |
Shipping Height | 3.40 |
Compliance & Notes
Harmonize Code | 8481.10.0090 |
See catalog page 351 for additional notes and/or restrictions.
Warranty Information
WARRANTY - Johnstone Supply will administer and promptly process all warranties in accordance with the manufacturer's specific warranty policies and procedures.
WHOLESALE ONLY - Identification is required of purchasers. Possession of Johnstone's catalog does not constitute an offer to sell by Johnstone or the right to purchase from us.
RETURNS - All returns are subject to a restocking charge.
- Brand Name:
- Robertshaw
Mfg. #: 720-406
Advertising
Part number 550-141-893/0800
10
AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual
Honeywell VR8205 and White-Rodgers 36E gas valves
FOR YOUR SAFETY READ BEFORE OPERATING
OPERATING INSTRUCTIONS
TO TURN OFF GAS TO THE APPLIANCE
•
Do not try to light any appliance.
•
Do not touch any electric switch; do not use
any phone in your building.
any phone in your building.
•
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
WHAT TO DO IF YOU SMELL GAS
1.
Robertshaw 7200er Gas Valve Manual Parts
Stop!
Read the safety information above on this label.
2. Set the thermostat to lowest setting.
Robertshaw Gas Control Valve Troubleshooting
3. Turn off all electrical power to the appliance.
4. Remove control access panel.
5. This appliance is equipped with an ignition device which automatically
lights the burner. Do not try to light the burner by hand.
6. Turn
gas control knob
clockwise
to
OFF
.
7. Wait five (5) minutes to clear out any gas. Then smell for gas, including
near the floor. If you smell gas,
STOP!
Follow
'B'
in the safety information
above. If you don't smell gas, go to the next step.
8. Turn
gas control knob
counterclockwise
to
ON
.
9. Turn on all electric power to the appliance.
10. Set thermostat to desired setting.
11. If the appliance will not operate, follow the instructions
'To Turn Off Gas
To Appliance'
![Robertshaw 7200er gas valve manual online Robertshaw 7200er gas valve manual online](https://anacsus.com/img/robertshaw-gas-valve-7000-manual-2.jpg)
below and call your service technician or gas supplier.
12. Replace control access panel.
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is to be performed.
3. Remove control access panel.
4. Turn
gas control knob
clockwise
to
OFF
. Do not force.
5. Replace control access panel.
A. This appliance is equipped with an ignition
device which automatically lights the pilot.
Do
not
try to light the pilot by hand.
Robertshaw 7000 Series Gas Valve
B. Before
OPERATING
, smell all around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than air
and will settle on the floor. See below.
the floor because some gas is heavier than air
and will settle on the floor. See below.
C. Biomecanica basica del sistema muscoesqueletico nordin pdf reader. Use only your hand to turn the gas control knob. Never use
tools. If the knob will not turn by hand, don't try to repair it,
call a qualified service technician. Force or attempted repair
may result in a fire or explosion.
call a qualified service technician. Force or attempted repair
may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control, which has been under water.
appliance and to replace any part of the control system and any
gas control, which has been under water.
If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
causing property damage, personal injury or loss of life.
88731
White-Rodgers
36E Gas valve
36E Gas valve
Honeywell
VR8205
Gas valve
VR8205
Gas valve
Position indicator
(shown in 'ON' position)
Gas control knob
Gas control knob
Position indicator
(shown in 'ON' position)
Operating instructions --